PrepAway - Latest Free Exam Questions & Answers

Which two statements about the EEM applet configuration are true?

Refer to the exhibit.

Which two statements about the EEM applet configuration are true? (Choose two.)

PrepAway - Latest Free Exam Questions & Answers

A.
The EEM applet runs before the CLI command is executed.

B.
The EEM applet runs after the CLI command is executed.

C.
The EEM applet requires a case-insensitive response.

D.
The running configuration is displayed only if the letter Y is entered at the CLI.

6 Comments on “Which two statements about the EEM applet configuration are true?

  1. Snoopy says:

    Admin: Please correct, the answer is A & D.

    sync
    Indicates whether the policy should be executed synchronously before the CLI command
    executes.
    nocase
    (Optional) Specifies case insensitive comparison.
    Here we see that the sync knob was enabled so A is correct. However, C is not correct as the
    nocase argument was not used, so the applet is configured to display the config only if a capital Y
    is issued.
    Reference.




    0



    0
  2. Theo says:

    Whether C is correct or not all depends on what they mean. They script does not require the person to enter a particular case because the script will convert it the correct case. However in order for the match to be true …. it has to be in uppercase. It’s kind of a BS answer. A and D are definitely correct though.




    0



    0
  3. 2ielony-ludek says:

    “A” is obviously correct.
    The C/D doubt is interesting, so I made a test.
    The applet works.
    If you answer “y” (lowercase) the config appears.
    According to that – C is true and D is false (“y” is not “Y”).




    0



    0