An engineer has several servers connected to the Storage Center through two FC fabrics. The Storage
Center runs in Virtual Ports mode. The engineer needs to create zones based on World Wide Names
(WWN).
Which WWNs from the Storage Center need to be included in the zone with the server WWN?

A.
only the Primary WWNs
B.
only the Virtual WWNs
C.
both the Primary and Reserve WWNs
D.
both the Virtual and Physical WWNs
I choose D
0
0
Correct answer is D
0
0
The correct answer is B.
0
0
in server zone only virtual wwn
B is correct
0
0
B
0
0
B
http://www.dell.com/support/manuals/us/en/19/dell-compellent-sc4020/sc4020om-v8/wwn-zoning-guidelines?guid=guid-66f1cd5c-3db0-44c2-9f2a-aef2f6896715&lang=en-us
0
0
B is correct, 100% sure
0
0
I confirm B is correct.
In virtual mode you need to configure:
* a zone with all SC physical wwns
* a zone with all SC virtual wwns
* a zone per server containing wwn server and SC virtual wwns.