If you install two Onboard Administrator modules with different firmware revisions in a c7000
enclosure, which module will be active by default?

A.
The one on the left of the enclosure
B.
The one on the right of the enclosure
C.
The one with the latest firmware, regardless of position
D.
The one with the original firmware regardless of position
Explanation:
Answers: A
the one on the left
Explanation:
Redundant Onboard Administrator modules
When two Onboard Administrator modules are installed, either module can be the active module.
The other becomes the standby module.
Configuration data is constantly replicated from the active Onboard Administrator module to the
standby Onboard Administrator module, regardless of the bay in which the active module currently
resides.
If you install two Onboard Administrator modules of the same firmware revision, the one on the left
of the enclosure will be the active one. If two Onboard Administrator modules installed into the
same enclosure have different firmware versions, the automatic configuration sync is disabled.
Both Onboard Administrator modules will put a clear entry into syslog stating exactlywhich version
is on which Onboard Administrator and how to upgrade them. However, the different firmware
versions do not affect which module is active or standby.
The same rules apply.