To configure high availability within a FAS8080 EX HA pair, which two statements are correct? (Choose two.)

A.
Connect the NVRAM HA interconnects between the nodes in the HA pair.
B.
Cable the cluster interconnects to the interconnect switch.
C.
Connect multiple FC paths from the controllers to the hosts.
D.
Connect both the local node and partner node to disk shelves using multipath HA.
Explanation:
A: If an NVRAM HA adapter fails, the node automatically fails over to its partner node. The partner (takeover)
node serves data for both of the nodes.
https://library.netapp.com/ecm/ecm_download_file/ECMP1610209
I’d choose A and D.
Does anybody have explanation why D is wrong and C is better?
If there is no HA multipath cabling the aggregates cannot be relocated.
I do not need to have multiple FC paths if I have only NAS conectivity. This condition is not mandatory for HA.
2
0
A , D
1
0
A , D
1
0
David, have you used this material to take the exam. I am taking mine in a couple days. did you have success
0
0
C cannot be correct.
I choose A & D
0
0
I think C is wrong because the questions say “high availability within” the HA pair. Nothing about high availability in the network.
0
0
A & D
1