The full boot cycle of the CN1610 should take approximately 50 seconds.
What should you do to minimize the interruption?

A.
Remove all of the cables from the CN1610 CL1 switch, and then connect them to different ports
on the CN1610 CL2 switch.
B.
You can migrate the cluster LIFs from the switch that is to be rebooted, and then revert the
cluster LIFs after the switch has finished rebooting.
C.
You can migrate Data LIFs to different ports on different nodes.
D.
On each respective switch, use the network interface migrate command to migrate the interswitch links.
Explanation:
LIFs are moved to other physical ports within the cluster to provide non-disruptive
services.
i think is B because CN1610 is the cluster switch not data
0
0
Correct Answer B
full boot cycle should take approximately 50 seconds. When the switch
reboots, the cluster LIFs will be automatically migrated to run on the
remaining switch and there will be some minor traffic interruption for less
than 10 seconds. To have less interruption, you can migrate the cluster LIFs
off of the switch that is to be upgraded, and then revert the cluster LIFs after
the switch has finished rebooting
0
0