which port is used for FCoE connections?
On a FAS8040, which port is used for FCoE connections?
what will happen if PDU-B fails?
Click the Exhibit button.
Referring to the diagram shown in the exhibit, what will happen if PDU-B fails?
What needs to be examined?
Hosts and switches are connected to a FAS8040. Multiple FC-enabled SVMs have been created, and LUNs have been mapped to multiple hosts. During failover
testing, one of the hosts lost connectivity to its LUNs.
What needs to be examined?
How would you add the other three LIFs?
Click the Exhibit button.
Based on the exhibit, you are configuring a 4-node cluster with an iSCSI LIF ob each node. You connect using the first LIF from a Windows Server 2012 host.
How would you add the other three LIFs?
What will accomplish this task?
You have a 4-node FAS8040 cluster licensed for FCP and iSCSI. Each node has both FC and iSCSI LIFs. One of your Windows 2012 Servers has a single 8Gb FC
port and a single 10 Gb Ethernet port with switched connectivity to the FC and Ethernet ports on the cluster. You need to use both ports on the host for multipath
access to a LUN on the NetApp cluster.
What will accomplish this task?
what must be configured on the host?
A customer has a clustered Data ONTAP solution and needs to connect several Windows 2012 servers using iSCSI for LUN access.
Before the LUN can be seen, what must be configured on the host?
What is the problem?
You have executed the following FC configuration workflow:
1. Verify IMT supported configuration.
2. Install VSC for VMware vSphere on a Windows Server.
3. Add the storage cluster to VSC and set recommended values.
4. Update host HBA firmware and BIOS.
5. Provision the LUN.
6. Manually create an igroup and add the host WWPNs into it.
7. Map the LUN to the igroup.
8. Create datastore and its containing LUNS and volumes.
In step 8, you are not able to see the LUNs you provisioned on your storage controller. When you run igroup show you see the ESX host’s initiators; however, they
are listed “not logged in”.
What is the problem?
which change must be made to make svm1 conform to iSCSI…
Click the Exhibit button.
You have a 2-node data ONTAP 8.3 cluster.
Based on the exhibit, which change must be made to make svm1 conform to iSCSI best practices?
cl01::> net int show –vserver
svm1 –data –protocol iscsi
Logical Status Network
Current Current Is
Vserver Interface Admin/Oper
Address/Mask Node Port Home
———– ———- ——
—- —————— —–
——– ——- —-
svm1
up/up 10.204.34.25/24 cl01-01
a0a 434 true
cl01::>iscsi show –vserver
svm1
Vserver: svm1
Target Name: iqn.1992 –
08.com.netapp: sn.ca5eaa069c211
Target Alias: svm1
Administrative Status: up
Which three environmental or physical requirements need…
Which three environmental or physical requirements need to be met when designing a SAN solution? (Choose three.)
Which three components should you verify?
You are verifying multipathing from the host to the storage controller.
Which three components should you verify? (Choose three.)