A customer has two redundant fabrics with four switches per fabric1 and each fabric has two
VSAN5.
What is the minimum number of out-of-band connections required by Fabric Manager to
discover and manage the fabrics?

A.
2
B.
4
C.
8
D.
16
You must be logged in to post a comment.
B
Explanation: Topology information is only gathered for the switch added as an out-of-band Fabric agent. The agent will not be able to gather the topology information for any connected switches unless they are also defined as out-of-band Fabric agents. If you are performing out-of-band discovery only on a fabric with several switches, you must install an out-of-band Fabric agent for each switch in the fabric to discover the whole fabric
0
0
Answer C. 2 redundants Fabrics per 4 switch each. Total 8 switch. You need install one out of band for each switch to discover and manage the fabrics.