They plan to upgrade to a DS5300, the maximum power consumption will be ____.
A customer has a DS4800 with five EXP810. They plan to upgrade to a DS5300, the maximum
power consumption will be ____.
What is a possible outcome when Media Scan detects an unrecovered media error on controller code revision 6.60
What is a possible outcome when Media Scan detects an unrecovered media error on controller
code revision 6.60.xx?
What should the minimum repository logical drive size be?
A customer is using FlashCopy to backup a 350GB logical drive. During the backup process, the
data will change by 68%. What should the minimum repository logical drive size be?
How should this be configured for enclosure loss protection?
When examining a profile you see the following: Drive at Enclosure 5, Slot 8 [mirrored pair with
drive at enclosure 5, slot 9] Drive at Enclosure 5, Slot 9 [mirrored pair with drive at enclosure 5,
slot 8]
How should this be configured for enclosure loss protection?
what is the default IP address of the Ethernet port 2 on controller A?
On a DS4000 what is the default IP address of the Ethernet port 2 on controller A?
which device could indicate that there is a connectivity issue?
A customer has just attached a new AIX 5.3 host to their DS4800 and allocating LUNs to the new
host. Assuming the new AIX host has two Host Bus Adapters (HBAs) with RDAC installed, which
device could indicate that there is a connectivity issue?
What is the first resource to consult to determine if the latest disk expansion model will attach to the DS480
A customer needs to add capacity to an existing DS4800 that has been in production for two years
and has eight EXP710 expansions attached. The additional capacity requires that another
expansion unit be added to the DS4800. What is the first resource to consult to determine if the
latest disk expansion model will attach to the DS4800?
What considerations do you have to point out to the customer?
You are installing a new DS4700 model 72 in direct attached environment with 2 2-node cluster
redundant attached. The customer is planning to setup a disaster recovery solution in the near
future by using SAN based replication. What considerations do you have to point out to the
customer?
what does "Immediate Availability Initialization (IAF) completed on logical drive" indicate?
In the Major Event Log (MEL) what does “Immediate Availability Initialization (IAF) completed on
logical drive” indicate?
What could have been used to prevent this mistake?
A customer has just received their new DS5300 systems. They attempt to place them into their
existing rack and discover that they are not going to fit in the available space. What could have
been used to prevent this mistake?