An engineer needs to install an SC8000 with four FC ports in each controller and two FC switches set up in
a dual fabric. Each controller also has two 10 Gb iSCSI ports. All iSCSI ports are connected to an ethernet
switch. The system uses virtual ports.
How many fault domains are required?

A.
3
B.
5
C.
4
D.
2
I have the same idea. C
0
0
Correct answer is C
0
0
in virtual port mode , allocation of fault domains is one domain per fabric .
so A is answer
0
0
but just have two fabric
0
0
sorry I dont saw the iscsi ethernet
0
0
A is the answer: 2 for FC ( one per fabric) and 1 for ISCSI (one switch)
0
0
A. question only mentioned 2 FC switch and 1 ISCSI switch. so it should be 3 fault domains.
0
0
in the ISCSI virtual domains use one Control Port per domain to redirect iSCSI traffic to the appropriate physical ports in that domain.
2 for FC and 1 for iSCSI (because have just one switch)
0