which statement is correct?
A ProfiNET management system operator is unable to see diagnostic information for a
Cisco Industrial Ethernet switch that has been added to a SIMATIC management station.
Based on the provided CLI output, which statement is correct?
switch# show profinet status
State : Enabled
Vlan : 201
Id : IE2000-Switch
Connected : Yes
ReductRatio : 128
GSD version : Mis-match
How are I/O timeout and Safety I/O timeout calculated?
How are I/O timeout and Safety I/O timeout calculated?
Which lines represent an I/O connection running at a 20…
Which CLI command will display IGMP snooping informatio…
Which CLI command will display IGMP snooping information in a Cisco IE2000 or Stratix 5700 switch?
What is preventing PanelView from pinging the other end…
A new device, PanelView, has been added to the network. See the table for device details:
All devices are able to ping their default gateway and all other devices except PanelView.
PanelView can only ping its default gateway.
After the administrator has done some investigation they have discovered the following information:
L3SW1# show run interface
interface Vlan1
no ip address
shutdown
interface Vlan191
ip address 10.10.27.125 255.255.255.192
ip helper-address 165.28.96.96
ip helper-address 165.28.32.235
no ip redirects
standby 191 ip 10.10.27.126
standby 191 priority 120
standby 191 preempt delay minimum 90
no ip route-cache
interface Vlan398
ip vrf forwarding mosaic
ip address 10.15.153.203 255.255.255.0
ip helper-address 10.15.154.252
ip helper-address 10.1.0.252
standby 98 ip 10.15.153.202
standby 98 priority 120
standby 98 preempt delay minimum 90
interface Vlan399
ip vrf forwarding mosaic
ip address 10.15.154.203 255.255.255.0
ip helper-address 10.1.0.252
ip helper-address 10.1.1.252
standby 99 ip 10.15.154.254
standby 99 priority 120
standby 99 preempt delay minimum 90
L3SW1# show ip route connected
10.0.0.0/8 is variably subnetted, 1149 subnets, 17 masks
C 10.10.27.64/26 is directly connected, Vlan191
C 10.10.31.254/32 is directly connected, Loopback1
What is preventing PanelView from pinging the other endpoints in the network?
Which three elements would enable high availability and…
Which statement is true regarding ProfiSAFE?
Which statement is true regarding ProfiSAFE?
Which four are alarms that can be configured for an int…
Cisco Industrial Ethernet switches are capable of sending alarm messages to ProfiNET management stations using the ProfiNET-IO protocol.
Which four are alarms that can be configured for an interface? (Choose four)
What are two reasons why REP is more suitable for the p…
It is common to use Resilient Ethernet Protocol (REP) on the manufacturing floor as a resiliency protocol, as opposed to the Enterprise where it is not generally deployed.
What are two reasons why REP is more suitable for the plant floor? (Choose two)
When do the changes you have made get published to the …
You are making changes to a Stratix 5700 using an Add On Profile (AOP) and a controller
which is on-line with RSLogix5000.
When do the changes you have made get published to the switch?