Why has the port gone error-disabled?

Refer to the exhibit.

An expansion project added an E-Tap and Device Level Ring to interface FastEthernet1/1
of L2SW1. The administrator has looked at the logs of L2SW1 and found that
FastEthernet1/1 was in an error-disabled state.Using command line access on L2SW1,
the administrator issued the following commands in configuration mode:

L2SW1(config)# interface FastEthernet 1/1
L2SW1(config-if)# shutdown
L2SW1(config-if)# no shutdown

The administrator checked the logs of L2SW1 and found the following:
Mar 30 02:23:17.588: %PM-4-ERR_DISABLE: bpduguard error detected on Fa1/1, putting
Fa1/1 in err-disable state

The administrator checked the software configuration of the switch port and found the following:
interface FastEthernet1/1
switchport access vlan 310
switchport mode access
speed 100
duplex full
no mdix auto
spanning-tree portfast
spanning-tree bpduguard enable

Why has the port gone error-disabled?

What is the next check that you ask the unskilled machi…

You are called at home at 3am by an unskilled machine operator with a suspected network
related problem; the controller LEDs are all normal but the output module’s
communications LED is not on. The operator has verfied the cable is functional and
correctly connected from the communication module to the switch.
What is the next check that you ask the unskilled machine operator to make?