the multivendor equipment?
A customer is connecting some new Cisco MDS switches to an existing Brocade SAN network.
The goal is to replace the existing Brocade switches with Cisco switches, while maintaining the
existing multivendor SAN fabric. What must be configured to use standard interoperability mo —between
the multivendor equipment?
What must you do to resolve the connectivity problems over the fc1/7 interface?
Refer to the below.
XPTO3# show interface fc1/7
Fc1/7 is down (Isolation due to domain overlap)
Hardware is Fibre Channel, WWN is
20:4e:00:05:30:00:63:9e
vsan is 10
Beacon is turned off
192 frames input, 3986 bytes, 0 discards
0 runts, 0 jabber, 0 too long, 0 too short
What must you do to resolve the connectivity problems over the fc1/7 interface?
Which option should you deploy to prevent man-in-the-middle attacks?
Refer to the exhibit.
Which option should you deploy to prevent man-in-the-middle attacks?
Exhibit:
Why is there no connectivity?
You have connected your Cisco MDS 9508 Switch to an existing McData SAN fabric using VSAN
100 You have changed the sWWN using McData OUI, deployed static DomainID 10, and
changed the VSAN 10 interoperability mode to 4. The Cisco MDS is having a connectivity problem
with the McData-based fabric. Why is there no connectivity?
the Brocade switch with core PID = 0 is used, without disruption to the existing network?
What would you do to connect the Nexus 5000 switch to the existing Fibre Channel SAN, where
the Brocade switch with core PID = 0 is used, without disruption to the existing network?
should the administrator use resolve the problem?
Refer to the exhibit.
The customer connects two switches or which the E_port does not come up. Which command
should the administrator use resolve the problem?
Exhibit:
using interoperability mode 4?
What must be changed when connecting the Cisco MDS Switch to an existing McData switch
using interoperability mode 4?
Which two options need to be configured on the MDS Switch?
A customer has some performance problems in their SAN environment. They want to use a Cisco
MDS 9000 Port Analyzer Adapter to connect to the Cisco MDS Switch to troubleshoot the
performance problems. Which two options need to be configured on the MDS Switch? (Choose
two.)
of the zoning information?
Which two Cisco MDS features allow fabric-wide consistent and VSAN-independent configurations
of the zoning information? (Choose two.)
Which feature detects hardware fault san dattempts recovery actions?
Which feature detects hardware fault san dattempts recovery actions?