PrepAway - Latest Free Exam Questions & Answers

How many seconds after the start of the first cycle will the next cycle start?

In a single-hop SRDF/AR setup, the options have been set as follows:
Cycle Time = 3000
Delay Time = 2000
Overflow = Next
The symreplicate session was started at time 0. The actual cycle time was 4500 seconds. How
many seconds after the start of the first cycle will the next cycle start?

PrepAway - Latest Free Exam Questions & Answers

A.
4500

B.
6000

C.
6500

D.
9000

Explanation:

One Comment on “How many seconds after the start of the first cycle will the next cycle start?

  1. Firas says:

    4500 Seconds for the first cycle to finish and then wait for 200 Seconds so the total will be 6500 seconds , since the overflow is next then the next cycle will not run immediatly and will run on the next cycle time which is 9000 so D is the correct answer




    0



    0

Leave a Reply