PrepAway - Latest Free Exam Questions & Answers

How many seconds after the start of the first cycle will the next cycle start?

In a single-hop SRDF/AR setup, the options have been set as follows:
Cycle Time = 3000
Delay Time = 2000
Overflow = Next
The symreplicate session was started at time 0. The actual cycle time was 4500 seconds. How
many seconds after the start of the first cycle will the next cycle start?

PrepAway - Latest Free Exam Questions & Answers

A.
4500

B.
6000

C.
6500

D.
9000

2 Comments on “How many seconds after the start of the first cycle will the next cycle start?

  1. jim says:

    9000 is correct. Explanation: Since the delay time of 2000 plus the actual run time of 4500 is 6500 (beyond the next schedule cycle time… the system will wait until the next scheduled start time at 9000.