During Fibre Channel adapter setup of a ESXi host, which configuration guideline should be considered?

PrepAway - Latest Free Exam Questions & Answers

A.
Do not mix Fibre Channel adapter models to access the same LUN from a single host unless the default
queue depth has been changed.

B.
Do not mix Fibre Channel adapters from different vendors in a single host.

C.
Use Fibre Channel adapters from different vendors in a single host.

D.
Set the queue depth to 16 if using a mix of different vendors’ Fibre Channel adapters in all hosts in the
cluster.

3 Comments on “which configuration guideline should be considered?

  1. vMan says:

    Typically, FC HBAs that you use on your ESXi host work correctly with the default configuration settings.

    You should follow the configuration guidelines provided by your storage array vendor. During FC HBA setup, consider the following issues.

    Do not mix FC HBAs from different vendors in a single host. Having different models of the same HBA is supported, but a single LUN cannot be accessed through two different HBA types, only through the same type.

    Ensure that the firmware level on each HBA is the same.

    Set the timeout value for detecting a failover. To ensure optimal performance, do not change the default value.

    ESXi supports 16 GB end-to-end Fibre Channel connectivity.

    https://docs.vmware.com/en/VMware-vSphere/6.5/com.vmware.vsphere.storage.doc/GUID-2BA05D27-9249-43A4-9B5D-D1F9DD8A7117.html