PrepAway - Latest Free Exam Questions & Answers

How many seconds does it take to detect a failure between two neighboring switches?

A network with five switches has been configured to run Rapid Spanning Tree Protocol (RSTP)
with default settings. How many seconds does it take to detect a failure between two neighboring
switches?

PrepAway - Latest Free Exam Questions & Answers

A.
2 seconds

B.
3 seconds

C.
6 seconds

D.
15 seconds

One Comment on “How many seconds does it take to detect a failure between two neighboring switches?

  1. p campos says:

    Answer is 6 seconds

    JNCIS-ENT Study Guide Chapter 3-14

    “If a neighboring bridge receives no BPDU with 3 times the hello interval
    (3 x 2 = 6 seconds), connectivity to the neighbor is faulty