What can the administrator do to help minimize similar errors?
A custom application program is submitted daily by operations personnel using the CALL
command. The program has a requirement that the prior days backup tape volume serial be
passed via a parameter so the program can read the tape. The program has failed due to syntax
errors when entering the CALL command and parameters.
What can the administrator do to help minimize similar errors?
What should the administrator do before restarting the save?
A customer selected option 21 from the SAVE menu, entered their tape library TAPMLBO1 and
selected to start the backup immediately. They receive the message “*MOUNTED not correct.”
What should the administrator do before restarting the save?
What is the most likely reason this occurred?
When installing the Group HIPER PTE5 (SE99709 for IBM i 7.1), the administrator discovered that
only the first PTE on the DVD was installed. What is the most likely reason this occurred?
What must the administrator take into consideration for this task?
A change to POWER7 server firmware is being planned on an HMC managed system. The current
server firmware level is AL720_108_066, and the new server firmware level will be
AL730_078_035.
What must the administrator take into consideration for this task?
Where can the service processor time setting be verified?
An administrator notices the time stamp of service processor-related messages are significantly
different from other time stamps from events known to have occurred at the same time.
The system is HMC managed.
The HMC time zone shows the correct local time
IBM i shows the correct local time.
Where can the service processor time setting be verified?
What is the cause of the degraded status?
A POWER7 customer using disk adapters with RAID-5 and hot spare has noticed sudden and
significant performance problems with an LPAR. WRKDSKSTS followed by Fl 1 shows the disk
units as “DEGRADED”. The customer has attempted to check the RAID card battery in Service
Tools but it is not listed.
What is the cause of the degraded status?
What should the administrator do to facilitate the change?
Programmers working on a software development project frequently need to save their
development library (LIBX) at the prior release level of the operating system.
The administrator needs to change the default value of the SAVLIB command parameter to
accommodate the programmers” prior release save requirement.
The default value before the change was: SAVLIB LIB(LIBX) TGTRLS(*CURRENT)
The default value after the change will be: SAVLIB LIB(LIBX) TGTRLS(*PRV)
What should the administrator do to facilitate the change?
Which option describes one of the purposes of a manual IPL?
Which option describes one of the purposes of a manual IPL?
What should be administrator do to improve performance?
On a system with a single ASP, an I/O intensive batch job that normally completes in 30 minutes is
still running after 2 hours. CPU utilization on the system is less than 10% and memory is not
constrained. The WRKDSKSTS command shows the following:
What should be administrator do to improve performance?
hown in the Index Advisor panel?
A database administrator completed a significant project to create appropriate indexes for an
application. The administrator needs to see if there are any indexes the Query Engine is calling for
which have not already been created.
How can the administrator ensure that only the new index requests will be shown in the Index
Advisor panel?