Which two of these represent the correct way to bind VSAN11 to interface vfc5 attached to interface Ethernet 1
You are troubleshooting an FCoE SAN boot issue on aCisco UCS C240 M3 server with a VIC 1225. Which
two of these represent the correct way to bind VSAN11 to interface vfc5 attached to interface Ethernet 1/5?
(Choose two.)
Which two pieces of information can you directly infer from the output of the show zone active command below?
You are troubleshooting an FCoE boot issue on a Cisco UCS C220 M3 server with a VIC 1225 CNA. Which
two pieces of information can you directly infer from the output of the show zone active command below?
(Choose two.)
zone name Server_1-to-Storage vsan 11
pwwn 50:06:01:60:3b:a0:08:9f [Storage]
* fcid 0x3b000b [pwwn 20:00:00:25:b5:04:0a:02] [C22_Server]
Which statement is true with respect to resetting aforgotten Cisco IMC admin password on a Cisco UCS CSeries r
Which statement is true with respect to resetting aforgotten Cisco IMC admin password on a Cisco UCS CSeries rack-mount server?
Which four tasks can be performed via Cisco IMC remote access to a Cisco UCS system?
Which four tasks can be performed via Cisco IMC remote access to a Cisco UCS system? (Choose four.)
Which remote access protocol is used by default to obtain CLI access to a Cisco UCS C-Series standalone server
Which remote access protocol is used by default to obtain CLI access to a Cisco UCS C-Series standalone
server?
Which actions on a Cisco UCS Server can be performed under the Cisco IMC utilities?
Which actions on a Cisco UCS Server can be performed under the Cisco IMC utilities? (Choose Four.)
What is the cause of the problem?
During the installation of Windows 2008 64-bit operating system on a Cisco UCS server, the RAID controller is
not found. What is the cause of the problem?
What is the cause of the problem?
A local storage installation of ESX on a Cisco UCS C-Series server has failed due to local storage issues.
What is the cause of the problem?
What is the cause of thisproblem?
A customer is trying to boot an operating system installed on a Cisco UCS B-Series blade server after a RAID1
cluster migration. The RAID LUN remains in inactivestate during and after the service profile association and
the server does not boot. What is the cause of thisproblem?
Which outcome will this command sequence produce?
A customer would like to create an Ethernet trafficmonitoring session on a Cisco UCS server to troubleshoot
network connectivity. The customer has entered the following commands via CLI:
UCS-A# scope eth-traffic-mon
UCS-A /eth-traffic-mon # scope fabric a
UCS-A /eth-traffic-mon/fabric # create eth-mon-session EthMonitor33
UCS-A /eth-traffic-mon/fabric/eth-mon-session* # create dest-interface 2 12
UCS-A /eth-traffic-mon/fabric/eth-mon-session/dest-interface* # set speed 20gbps
UCS-A /eth-traffic-mon/fabric/eth-mon-session/dest-interface* # commit-buffer
UCS-A /eth-traffic-mon/fabric/eth-mon-session/dest-interface #
Which outcome will this command sequence produce?