PrepAway - Latest Free Exam Questions & Answers

Category: NS0-506

Exam NS0-506: NetApp Certified Implementation Engineer—SAN, ONTAP

What is the problem?

You have executed the following FC configuration workflow:
1. Verify IMT supported configuration.
2. Install VSC for VMware vSphere on a Windows Server.
3. Add the storage cluster to VSC and set recommended values.
4. Update host HBA firmware and BIOS.
5. Provision the LUN.

6. Manually create an igroup and add the host WWPNs into it.
7. Map the LUN to the igroup.
8. Create datastore and its containing LUNS and volumes.
In step 8, you are not able to see the LUNs you provisioned on your storage controller. When you run igroup show you see the ESX host’s initiators; however, they
are listed “not logged in”.
What is the problem?

which change must be made to make svm1 conform to iSCSI…

Click the Exhibit button.
You have a 2-node data ONTAP 8.3 cluster.
Based on the exhibit, which change must be made to make svm1 conform to iSCSI best practices?
cl01::> net int show –vserver
svm1 –data –protocol iscsi
Logical Status Network
Current Current Is
Vserver Interface Admin/Oper
Address/Mask Node Port Home
———– ———- ——
—- —————— —–
——– ——- —-
svm1
up/up 10.204.34.25/24 cl01-01
a0a 434 true
cl01::>iscsi show –vserver
svm1
Vserver: svm1
Target Name: iqn.1992 –
08.com.netapp: sn.ca5eaa069c211
Target Alias: svm1

Administrative Status: up


Page 1 of 512345