Which command would you use to perform the giveback?
A 2 node cluster (Node-1 and Node-2) has suffered a takeover event. The down node (Node-1) is
currently waiting for giveback. However, it is unsure if the node will boot successfully. The client suffer any
data outage.
Which command would you use to perform the giveback?
Which action will solve the problem in this scenario?
SnapDrive for Windows has been installed and configured on a VMware virtual machine. The virtual
machine has been configured with raw device mappings (RDMs) that are mapped to LUNs on a NetApp
storage controller. The RDMs can be seen as connected disks in Windows Disk Management.
However, SnapDrive is not enumerating the RDMs.
Which action will solve the problem in this scenario?
Which two types of output would be used first to solve …
You are trying to determine why AutoSupport notifications are not being sent. Which two types of output
would be used first to solve this problem? (Choose two.)
what information should the customer collect from the R…
A customer explains that their V3170 NetApp controller has failed over and they do not know what to do
next.
In this scenario, what information should the customer collect from the Remote LAN Module (RLM) and
send to you? (Choose two.)
which two steps are part of that plan?
You have a 6-node cluster with six identical controllers. You are upgrading from clustered Data ONTAP
8.3.1 to clustered Data ONTAP 8.3.2. From the Upgrade Advisor, you downloaded the upgrade plan.
In this scenario, which two steps are part of that plan? (Choose two.)
which statement describes the problem?
A customer mentions that their Windows users cannot access clustered Data ONTAP 8.3.1 CIFS shares.
The users see “access denied” on the Windows side. Host name resolution is working and properly
resolves IP to host name and host name to IP and the customer can ping using host name and IP.
In this scenario, which statement describes the problem?
Which two clustered Data ONTAP daemons would be at faul…
A customer cannot create a new volume from OnCommand System Manager.
Which two clustered Data ONTAP daemons would be at fault in this scenario? (Choose two.)
what is the cause of this error?
A customer has replaced both interconnect cables on a FAS3240 HA pair with IOXM because they were
damaged. After replacing the cables, the customer receives the error shown below.
“HA interconnect port 1 of this appliance seems to be connected to port 2 on the partner appliance.”
In this scenario what is the cause of this error?
which two actions would you perform to obtain more info…
You receive the AutoSupport message, “CONTROLLER TAKEOVER COMPLETE PANIC” from a
FAS3250 controller. You suspect a hardware issue. A core file was written to disk.
In this scenario, which two actions would you perform to obtain more information? (Choose two.)