what is the reason?
You are attempting to merge two Brocade VDX switches running in fabric mode, but they
segment.
sw0# show fabric islports
Name: sw0
Type: 96.5
State: Online
Role: Fabric Principal
VCS Id: 10
Config Mode:Distributed
Rbridge-id: 4
WWN: 10:00:00:05:33:91:48:f7
FCF MAC: 00:05:33:91:48:f7
<truncated output>
sw0# show fabric islports
Name: sw0
Type: 96.5
State: Online
Role: Fabric Principal
VCS Id: 2
Config Mode:Distributed
Rbridge-id: 20
WWN: 10:00:00:05:33:90:92:e4
FCF MAC: 00:05:33:90:92:e4
<truncated output>
Referring to the exhibit, what is the reason?
what is the reason?
You are attempting to merge two Brocade VDX switches, both running in fabric mode, but
they segment. sw0# show fabric islports
Name: sw0
Type: 96.5
State: Online
Role: Fabric Principal
VCS Id: 10
Config Mode:Local-only
Rbridge-id: 4
WWN: 10:00:00:05:33:91:48:f7
FCF MAC: 00:05:33:91:48:f7
<truncated output>
sw0# show fabric islports
Name: sw0
Type: 96.5
State: Online
Role: Fabric Principal
VCS Id: 10
Config Mode:Distributed
Rbridge-id: 20
WWN: 10:00:00:05:33:90:92:e4
FCF MAC: 00:05:33:90:92:e4
<truncated output>
Referring to the exhibit, what is the reason?
Which switch will become the multicast root if no other device has the priority set?
You have a Brocade VCS Fabric and one Brocade VDX has the multicast root manually
assigned with the highest priority. You are going to remove that VDX from the fabric. Which
switch will become the multicast root if no other device has the priority set?
Which two switch changes, depending upon the hypervisor platform, should be used to correct the 20 Gbps connec
A customer would like to increase the bandwidth to servers connected to a Brocade VCS
Fabric. Two 10 Gbps NICs to the server were teamed, but now there is no IP connectivity to
the Brocade VDX 6740. Which two switch changes, depending upon the hypervisor platform,
should be used to correct the 20 Gbps connection to the server? (Choose two.)
what is the cause of the discarded packets on the port channel from the core?
Your customer has performance problems and suspects dropped packets between the core
router and the Brocade VCS Fabric. You determine that port Te 1/0/5 is connected to an old
database server with a high transaction rate. VDX1# show interface stats brief
Packets Error Discards CRC
Interface rx tx rx tx rx tx rx
Po 10 2013637 13726949 0 0 21668 0 0
Po 20 2215053 15608689 0 0 0 2 0
Te 1/0/1 1130905 12884896 0 0 21463 0 0
Te 1/0/5 39857 63074 0 0 0 0 0
<truncated output>
Referring to the exhibit, what is the cause of the discarded packets on the port channel from
the core?
which statement is true?
Your customer wants to establish a LAG connection on a Brocade VDX 6740T-1G
connecting to another vendor’s switch using 1 GbE interfaces. Every time they try to enable
the port channel, the interfaces shut down. In this situation, which statement is true?
What is a reason for this problem?
You just connected a new Brocade VDX 6740T-1G switch to the top of rack. You want to
connect two 40 GbE uplinks to VDX1 and two 40 GbE uplinks to VDX2. Two of the links
come online and two of them are segmented. What is a reason for this problem?
which two steps are required?
You want to create trunks with your existing 40 GbE ISL connections between two Brocade
VDX 8770s using NOS 4.1.1. The two VDX 8770s are not forming a trunk as expected.
VDX8770# sh fab isl
Rbridge-id: 131 #ISLs: 2
Src Src Nbr Nbr
Index Interface Index Interface Nbr-WWN BW Trunk Nbr-Name
———————————————————————————————-
13 Fo 131/2/1 8 Fo 132/2/1 10:00:00:05:33:D4:0C:CE 40G Yes “sw-0”
15 Fo 131/2/2 45 Fo 132/2/2 10:00:00:05:33:D4:0C:CE 40G Yes “sw-0”
Referring to the exhibit, which two steps are required? (Choose two.)
What information should you send?
You see a large number of alerts in Brocade Network Advisor on a Brocade VDX switch.
You are asked to gather information to send to technical support for analysis.
What information should you send? (Choose three.)