Which two statements are correct?
You want to examine packets in transit across links to troubleshoot the traffic pattern on a
specific port using SPAN on a Brocade VDX 6730-76. You configure a monitor session with
source interface Te 1/0/10 and destination interface Te 1/0/21. Which two statements are
correct? (Choose two.)
What do these two errors indicate?
Brocade Network Advisor has notified you that one of your ISLs between two Brocade VDXs
is reporting a high number of errors. You log into the switch and clear the counters. You
notice that the CRC and error counters are incrementing at a high rate. What do these two
errors indicate? (Choose two.)
What are two reasons for the problem?
Referring to the exhibit, you are experiencing latency issues on interface Te 27/0/60.
switch# show interface tengigabitethernet 27/0/60
TenGigabitEthernet 27/0/60 is up, line protocol is up (connected)
Hardware is Ethernet, address is 0005.3367.26d8
Current address is 0005.3367.26d8
Pluggable media present
Interface index (ifindex) is 283874428169
MTU 2500 bytes
LineSpeed Actual : 10000 Mbit
LineSpeed Configured : Auto, Duplex: Full
Flowcontrol rx: off, tx: off
Last clearing of show interface counters: 22:07:59
Queueing strategy: fifo
Receive Statistics:
15254 packets, 1395269 bytes
Unicasts: 10641, Multicasts: 2637, Broadcasts: 1976
64-byte pkts: 10874, Over 64-byte pkts: 3294, Over 127-byte pkts: 117
Over 255-byte pkts: 969, Over 511 -byte pkts: 0, Over 1023-byte pkts: 0
Over 1518-byte pkts(Jumbo): 0
Runts: 0, Jabbers: 0, CRC: 1128350, Overruns: 0
Errors: 1128350, Discards: 0
Transmit Statistics:
12633 packets, 1155963 bytes
Unicasts: 18, Multicasts: 12615, Broadcasts: 0
Underruns: 0
Errors: 0, Discards: 0
Rate info (interval 299 seconds):
Input 0.000128 Mbits/sec, 0 packets/sec, 0.00% of line-rate
Output 0.000000 Mbits/sec, 0 packets/sec, 0.00% of line-rate
Time since last interface status change: 0d00h40m
What are two reasons for the problem? (Choose two.)
What are two reasons?
What is the reason for this happening?
You are configuring a Brocade VDX 6730-76 and only 50 of the Ethernet ports are currently
working. What is the reason for this happening?
Which two steps should be completed to replace the faulty switch?
One of the switches in your Brocade VCS Fabric in logical chassis mode needs to be
replaced. After configuring the replacement switch with the same VCS RBridge ID of the
faulty switch, you attempt to replace the faulty switch with a new one but find the switch is
segmented from the fabric. Which two steps should be completed to replace the faulty
switch? (Choose two.)
What would you do to resolve the problem?
You want to remove one of your Brocade VDX 6740s from your VCS fabric in Logical
Chassis mode. You issue the no vcs enable command on the VDX 6740 but the switch is not
removed. What would you do to resolve the problem?
Which protocol should be active?
You are troubleshooting connectivity problems with a Brocade VCS Fabric connecting to a
VM
ESXi host. You want to see the interfaces for dvSwitch shown in the exhibit.
VDX8770_3-131# show vnetwork dvs vcenter vcenter-1 -69
dvSwitch Datacenter Host Uplink Name Switch Interface
=============== ==================== =========== ==============
====================
dvSwitch datacenter-21 TESTHOST3 vmnic4 –
vmnic5 –
TESTHOST4 vmnic4 –
vmnic5 –
dvSwitch2 datacenter-21 TESTHOST3 vmnic6 Te 179/0/3
TESTHOST4 vmnic7 Te 160/0/3
Which protocol should be active?
What should the customer do to bring the vLAG online?
A customer has a four-port vLAG between two VDX switches and a server. Two of the four
links
are up but the vLAG will not come up.
VDX8770_3-131# show interface po 710
Port-channel 710 is up, line protocol is down (link protocol down)
Hardware is AGGREGATE, address is 0005.33d4.0d2c
Current address is 0005.33d4.0d2c
Interface index (ifindex) is 671089350
Minimum number of links to bring Port-channel up is 3
MTU 2500 bytes
LineSpeed Actual : Nil
Allowed Member Speed : 10000 Mbit
Priority Tag disable
IPv6 RA Guard disable
Last clearing of show interface counters: 2d05h53m
Queueing strategy: fifo
Receive Statistics:
0 packets, 0 bytes
Unicasts: 0, Multicasts: 0, Broadcasts: 0
64-byte pkts: 0, Over 64-byte pkts: 0, Over 127-byte pkts: 0
Over 255-byte pkts: 0, Over 511 -byte pkts: 0, Over 1023-byte pkts: 0
Over 1518-byte pkts(Jumbo): 0
Runts: 0, Jabbers: 0, CRC: 0, Overruns: 0
Errors: 0, Discards: 0
Transmit Statistics:
0 packets, 0 bytes
Unicasts: 0, Multicasts: 0, Broadcasts: 0
Underruns: 0
Errors: 0, Discards: 0
Rate info (interval 299 seconds):
Input 0.000000 Mbits/sec, 0 packets/sec, 0.00% of line-rate
Output 0.000000 Mbits/sec, 0 packets/sec, 0.00% of line-rate
Time since last interface status change: 2d05h53m
What should the customer do to bring the vLAG online?
what is the reason?
You are attempting to merge two Brocade VDX switches, both running in fabric mode, but
they segment. sw0# show fabric islports
Name: sw0
Type: 96.5
State: Online
Role: Fabric Principal
VCS Id: 10
Config Mode:Distributed
Rbridge-id: 4
WWN: 10:00:00:05:33:91:48:f7
FCF MAC: 00:05:33:91:48:f7
<truncated output>
sw0# show fabric islports
Name: sw0
Type: 96.5
State: Online
Role: Fabric Principal
VCS Id: 10
Config Mode:Distributed
Rbridge-id: 4
WWN: 10:00:00:05:33:90:92:e4
FCF MAC: 00:05:33:90:92:e4
<truncated output>
Referring to the exhibit, what is the reason?