which three sFlowrelated tasks?
When sFlow is enabled on a Brocade FastIron switch, the system performs which three sFlowrelated tasks? (Choose three.)
What are two advantages?
Your company must migrate data to a new data center 100 km away. You decide to use an FCIPshared infrastructure instead of dark fiber.
What are two advantages? (Choose two.)
Which solution will satisfy the requirements?
You need to implement an IP network solution to manage IP switches and routers that includes
call home and e-mail notification. Which solution will satisfy the requirements?
Which three technologies extend FC fabrics?
Which three technologies extend FC fabrics? (Choose three.)
Which distance buffer credit allocation mode would you configure if you do not know the distance of the link
Which distance buffer credit allocation mode would you configure if you do not know the distance
of the link, and want the switch to calculate and select the optimum buffer credits for the port?
Which two port configuration parameters on the Brocade FastIron would cause this condition?
You made some network changes on one of your Brocade FastIron switches and you lost the link
to several small mini-switches on the office floor. You execute a show interfaces brief and it
returns the following output:
Port Link State Dupl Speed Trunk Tag Pvid Pri MAC Name
1/3/1 ERR-DIS None None None 129 Yes N/A 0 0024.38be.dc33
1/3/2 ERR-DIS None None None 129 Yes N/A 0 0024.38be.dc33
Which two port configuration parameters on the Brocade FastIron would cause this condition?
(Choose two.)
Which two Brocade Fabric OS v7.0 features must be disabled when configuring a port for distance using a Time D
Which two Brocade Fabric OS v7.0 features must be disabled when configuring a port for distance
using a Time Division Multiplexing (TDM) third-party link that requires ISL R_RDY?
Which feature will resolve this problem?
On your Brocade MLXe, you experience a large number of BGP routes being advertised and
withdrawn from your downstream ISP. You need to prevent this from constantly happening.
Which feature will resolve this problem?
What is a common reason for this performance problem over the distance link?
You have allocated the correct number of buffers for your distance and speed on an extended
distance link over dark fiber. However, you notice that there is a latency issue being reported on
the port. The port is repeatedly buffer starved.
What is a common reason for this performance problem over the distance link?
Which parameter must be configured?
You have configured Rapid Spanning Tree (802.1w) on your VLANs. You notice delays of 30
seconds or more before workstation and server ports start to send and receive traffic after a
change in topology. Which parameter must be configured?