A customer observes write latencies above 40 ms on a clustered Data ONTAP system with two
FAS3220s for a period of several minutes each night. During performance analysis, you discover that
several back-to-back CPs occur
In this scenario, which two configuration changes will reduce the write latencies? (Choose two.)
A.
Move the volume with the highest write load to an aggregate with faster disks.
B.
Migrate the LIF with the highest network receive rate to a faster port.
C.
Add more disks to the aggregate.
D.
Add flash cache cards to the nodes.