What is the cause of the failure?
An existing machine is configured with redundant VIO Servers with SEA failover. A number of
VLANs are already configured and used by the hosted client LPARs. Two additional VLANs are
required to be added to the deployment to support new growth.
An administrator uses a DLPAR operation to add the additional VLANs to the existing Virtual
Ethernet adapters. The attempt failed. They have updated the LPAR profile for both VIO Servers.
Next they shutdown one of the VIO Servers and attempt to reactivate the LPAR. The following
error is displayed:
“HSCL0282 The virtual Ethernet adapter in virtual I/O slot 11 can’t be defined because the
partition with ID 2 already defines a trunk adapter in its virtual I/O slot 11. Please modify the profile
accordingly and reactivate the partition.”
What is the cause of the failure?
What should be done to allow them to access the external network?
How can an administrator list all VIO server (VIOS) commands run by any user?
How can an administrator list all VIO server (VIOS) commands run by any user?
Which command will achieve this?
After installing a new VIO server partition an administrator noticed that the time zone is incorrectly
set to CST6DST. The administrator would like the time zone set to Europe/London. Which
command will achieve this?
Which of the following is the most cost-efficient configuration for the VIO client?
A dedicated LPAR has two dedicated Fibre Channel HBAs assigned to it.
In order to reduce the amount of hardware, the LPAR will be migrated to a currently running VIO
server.
The administrator collects some server performance from the VIO server and notices that the I/O
peaks at 5.5Gbits and runs at an average of 4Gbits per second.
The VIO Server runs two dual port 8Gbit FCS cards, so the load is not affected by other LPARS
on the VIO Server.
Which of the following is the most cost-efficient configuration for the VIO client?
what steps are required?
When installing a Linux LPAR from an AIX NIM server, what steps are required?
What Active Memory Expansion factor should be set for the Hypervisor to target 40GB of memory?
An application requires 40GB of memory, but only 20GB of memory can be allocated to the
partition.
What Active Memory Expansion factor should be set for the Hypervisor to target 40GB of
memory?
Which of the following statements about PowerVM Lx86 is true?
An administrator is interested in installing PowerVM Lx86 software on a new Power 770 for a proof
of concept. Which of the following statements about PowerVM Lx86 is true?
Which one of the following could explain this?
After restoring a mksysb image from a NIM server, an administrator noticed that the SEA interface
had not been successfully reconfigured.
Which one of the following could explain this?