PrepAway - Latest Free Exam Questions & Answers

Tag: Exam E20-816 (update October 25th, 2015)

Exam E20-816: Symmetrix Solutions Expert Exam for Technology Architects (update October 25th, 2015)

How should all the devices be configured on the target Symmetrix VMAX storage array?

You are designing a new Symmetrix VMAX storage array to replace a client’s Symmetrix
DMX4. Performance data is captured and examined for the DMX4. During the discovery
phase, the client states that their critical business application has increased response times
when establishing SRDF for 20 logical volumes. Examination of the current configuration of
the logical volumes used for the application reveals the following: – Ten 4way meta volumes
at 200 GB – Five 8 way meta volumes at 472 GB – Five logical volumes at 59 GB
Performance analysis shows that the device write pending counts for the five logical
volumes at 59 GB are higher than other volumes used by the application. The client expects

migration events to require a complete establishment of their DR environment logical
volumes. How should all the devices be configured on the target Symmetrix VMAX storage
array?

Which metavolume configuration should you use?

You are planning a VMAX configuration with FAST VP for a customer’s Exchange 2010
environment. The customer requests the database be placed on thin devices and the log
files be placed on regular devices. Some of volumes are quite large and will require
metavolumes to meet the capacity requirements. Which metavolume configuration should
you use?

Which RAID level(s) should be used for the control files, data files, redo logs and archive logs?

A new Symmetrix array is being designed for an Oracle data warehouse. The workload is
expected to be primarily reads for batch reporting. The customer wants to maximize usable
capacity of the array and follow best practices for RAID types to optimize performance.
Which RAID level(s) should be used for the control files, data files, redo logs and archive
logs?

What is the likely cause?

A new EMC customer recently installed their first VMAX and a complete suite of EMC
management tools. Their lead capacity planner attended training and has started monitoring
the VMAX. You receive a call and this person describes the measurements observed.
During the period of heaviest workload, reported I/O rates on certain Fibre Channel ports is
nearing 2,000/second but those ports only display about 10% utilization. What is the likely
cause?

How should DCP be configured to separate the write-intensive workload from the other applications?

A customer has an environment where one application has a very high, sequential,

write-intensive workload. They would like to use Dynamic Cache Partitioning to isolate this
workload from the other applications. How should DCP be configured to separate the
write-intensive workload from the other applications?