How much data is moved during a VLUN VP Migration of a 500 GB virtual LUN, 80% preallocated, and containing 38
How much data is moved during a VLUN VP Migration of a 500 GB virtual LUN, 80% preallocated, and containing 382 GB of user data?
What is the underlying technology that makes virtual LUN Migration DP possible?
What is the underlying technology that makes virtual LUN Migration DP possible?
How are both the source and target volumes specified when using SYMCLI?
A Symmetrix storage administrator wants to use Virtual LUN Migration DP to migrate data
between storage tiers. How are both the source and target volumes specified when using
SYMCLI?
How many mirror positions will remain for the R1 devices in this configuration?
A customer wants to deploy concurrent SRDF with RAID-1 R1 devices in a Symmetrix VMAX
array. TimeFinder/Mirror scripts and RAID-1 BCVs will be used to take local point-in-time copies of
the R1 devices. How many mirror positions will remain for the R1 devices in this configuration?
How many mirror positions will remain for the R1 devices in this configuration?
A customer wants to deploy SRDF/S between a pair of Symmetrix VMAX arrays. The R1/R2
devices will be RAID-1 protected. Two RAID-1 BCVs will be concurrently established with the R1
device. How many mirror positions will remain for the R1 devices in this configuration?
—-A. 0
What is the maximum number of tiers that can be included in a policy?
A customer is trying to create a FAST policy for automated tier management. They create a set of
six tiers for their new Symmetrix VMAX. When the customer tries to build a policy with six tiers of
storage, it fails.
What is the maximum number of tiers that can be included in a policy?
Which factor has the strongest influence on the decision?
A customer wants to understand if FAST is a technology they should implement on their new
Symmetrix VMAX. The application has the following I/O profile:
2000 IOPS
4:1 Read/Write ratio
10 thin LUNs in 500 GB data volume
4 FA ports connected to the host
Which factor has the strongest influence on the decision?
What has the strongest influence on the decision to implement FAST VP?
A customer has the following configuration for an application on a Symmetrix VMAX storage array:
300 IOPS
1:1 Read/Write ratio
5 thin LUNs in a 500 GB data volume
300 FC drives in the thin pool
2 FA ports connected to the host
What has the strongest influence on the decision to implement FAST VP?
What is an accurate statement about dynamic Symmetrix tiers?
What is an accurate statement about dynamic Symmetrix tiers?
Which emulation(s) are supported by FAST VP?
Which emulation(s) are supported by FAST VP?