A data center company is using two EMC NetWorker servers (NetWorker_A and NetWorker_B).
Each server has three storage nodes to protect 650 server applications and data. The total
amount of data being backed up is 100 TB. NetWorker_A server protects 60 TB and NetWorker_B
server protects 40 TB.
To minimize cost and ease licensing management for NetWorker, the company decided to switch
from a traditional licensing model to a capacity licensing model. How many licenses are needed to
support the company’s requirements?

A.
2 Source Capacity Datazone Enabler and Source Capacity 10 TB tier 4 licenses
B.
2 Source Capacity Datazone Enabler and Source Capacity 10 TB tier 3 licenses
C.
2 Base license and 10 Source Capacity TB tier 3 licenses
D.
2 Source Capacity Datazone Enabler and 650 Standard Client Connection licenses
ReferencE.http://slyvonne.blogspot.com/2012/04/emc-networker-capacity-licensing.html(question no.1 and 2)
none of these answers are correct.
0
0
answer B is
0
0
you are right, capacity is not correct in B
0
0
Why do you want to know whether B is a correct answer?
https://twitter.com/v_wonderful_v
0
0
Correct is B. According to the table of the types of licenses for NW.
a- NetWorker Source Capacity 10TB License Tier 4 (101 – 250TB) out of range.
b – NetWorker Source Capacity 10TB License Tier 3 (51 – 100TB)
c – 2 base line licenses… no correct.
d- License for capacity or traditional license, no mixed.
0
0