PrepAway - Latest Free Exam Questions & Answers

Category: E20-324

Exam EMC E20-324: VNX Solutions Design Exam for Technology Architects

In your scenario, which hot spare drive would the array first select to replace the failed drive?

After reviewing the design for their new VNX, your customer has requested further explanation of the hot spare algorithm used by the array. You propose the following scenario:

RAID group 200 consists of five 600 GB 10K SAS drives in a RAID 5 configuration. Within this RAID group there are three 25 GiB LUNs. One of the five drives has just failed.

In your scenario, which hot spare drive would the array first select to replace the failed drive?

Which configuration best supports their availability requirements?

Your customer has just purchased a new VNX, which will be dedicated to their large SQL 2008 cluster. High-performance and high-availability are critical.

To meet their availability requirements, the customer has requested the configuration be optimized to allow both storage processors to process I/O for any given LUN without trespassing the LUN.

Which configuration best supports their availability requirements?

Which protocol should be used to connect the servers to the storage array?

Your customer has two clustered SQL servers that require direct access to LUNs located on their VNX storage array.

Both servers are located in the customer’s main office. The VNX storage array is located in the customer’s data center, which is approximately 1.5 km from their office. Both facilities are interconnected using their existing IP network.

Which protocol should be used to connect the servers to the storage array?

How will that data be distributed (numbers are approximate)?

Click on the calculator icon in the upper left-hand corner. A customer has a heterogeneous pool with the following configuration:

– 1000 GiB of Flash, with 400 GiB free
– 10,000 GiB of SAS, with 2,000 GiB free
– 80,000 GiB of NL-SAS, with 20,000 GiB free

The customer creates a new LUN with data placement policy set to “auto-tiering”. The LUN is then populated it with 500 GiB of data. How will that data be distributed (numbers are approximate)?

How is that data distributed (numbers are approximate)?

Click on the calculator icon in the upper left-hand corner. A customer has a heterogeneous pool with the following configuration:

– 800 GiB of Flash, with 300 GiB free
– 12,000 GiB of SAS, with 2,000 GiB free
– 50,000 GiB of NL-SAS, with 25,000 GiB free
The customer creates a new LUN with data placement policy set to “highest available tier”. The LUN is then populated with 600 GiB of data. How is that data distributed (numbers are approximate)?

What is the minimum size of FAST Cache recommended for this environment?

Click on the calculator icon in the upper left-hand corner. A customer has four (4) LUNs of 500 GiB each, six (6) LUNs of 250 GiB each, and five (5) LUNs of 100 GiB each. All the drives presently in their VNX system are SAS and NL-SAS. They wish to implement FAST Cache. Your data collection shows the skew to be 95%. What is the minimum size of FAST Cache recommended for this environment?


Page 8 of 12« First...678910...Last »