PrepAway - Latest Free Exam Questions & Answers

Category: E20-880

Exam E20-880: EMC VNX Solutions Expert Exam for Technology Architects Exam

which configuration best assigns the workloads?

Your customer has a new VNX solution configured with Flash, SAS, and NL-SAS drives. The
customer requires their DSS, VDI, Software Development, and Regulatory Compliance workloads
to be distributed between the different drive types. Due to limited drive quantities only one

workload type can be configured using Flash drives.
According to best practices, which configuration best assigns the workloads?

Which Unisphere Analyzer counter would provide the most useful insight into the issue?

An application owner is concerned about the performance of a set of application servers. The
applications generate a large amount of small I/O. Disk and LUN response times appear to be
acceptable for the servers in question. The servers are all Windows hosts using QLogic HBAs with
the default EMC driver settings.
Which Unisphere Analyzer counter would provide the most useful insight into the issue?

what is the minimum number of RAID Groups required?

Your customer has recently purchased a VNX to host their three Oracle RAC database
environments and automated payment processing application. The RACs and application are
differentiated as follows: ORA-PROD, ORA-STAGE, ORA-DEV, APP-PROD, APP-STAGE, and
APP-DEV.
The customer has provided you with their Enterprise Storage Policy (ESP) and is requesting that
you adhere to this policy when architecting their new VNX solution. The ESP states the following
as it relates to Oracle database storage requirements:
All LUNs must be configured as raw devices
All LUNs must be managed using ASM
No fewer than two LUNs per ASM disk group
No more than one database per RAC per RAID Group
No more than three databases per RAID group
All data LUNs must be 1000 GiB RAID 5
All FRA LUNs must be 500 GiB RAID 1/0

No more than eight total disks per RAID Group
No fewer than four disks per RAID Group
Based on the ESP, and assuming ORA-PROD has six instances, what is the minimum number of
RAID Groups required?

what compression ratio will the client typically see?

You designed the disk layout on a VNX storage system for a large client. They have a very large
amount of basic file data consisting of Word documents and text files. The data needs to be
accessible but sits for long periods of time without activity.
You decided to place this data on a thin LUN and compress it to maximize capacity. The client is
concerned about how much capacity they will reclaim with compression.
Based on the data that is going to be placed on the compressed LUN, what compression ratio will
the client typically see?


Page 10 of 13« First...89101112...Last »