which two [2] features are to be recommended?
You have just completed a basic implementation of an NS700 with 30 FC and 30 ATA drives. The
customer has been using the EMC CLARiiON and Connectrix products for some time. She
mentions that they are looking to lower the backup storage cost, which includes their Exchange
2003 Servers. If asked, which two [2] features are to be recommended?
What size must the SavVol be to accommodate the changes?
You would like to run Celerra Replicator on one of your production file systems. You found from
watching the last incremental backup that you have a change rate of 2% a day on that file system.
The file system size is 100 GB. You want to calculate the size of the SavVol to be able to continue
with replication even if you have a 4 day network outage between the source and destination site.
What size must the SavVol be to accommodate the changes?
Why does the Celerra NOT boot up?
What could have caused the move?
Several file systems were replicated. After customer verification, the replicated file systems were
put into production. An hour later, the datamover panicked causing a reboot. After the reboot,
users started complaining of missing files on one file system.
The customer thought it was an unsuccessful replication. We found the reported missing files in
the lost+found directory. What could have caused the move?
How would you fix this problem?
Which tool would you use to migrate this filesystem?
You need to migrate your customer’s filesystem from a Windows Server to a new Celerra. The
customer’s data includes a lot of .pst files and they need to do this with as little down time as
possible. Which tool would you use to migrate this filesystem?
What could be the cause?
Your customer has implemented HighRoad and they are having performance problems. What
could be the cause?
What could be causing his performance issues?
Your customer recently configured new network connections on his newly installed Celerra. He
can access data on all interfaces but is reporting performance problems.
Your customer sends you ifconfig outputs from the Celerra and client machines. What could be
causing his performance issues?
Which two [2] network protocols does the Celerra support?
Which two [2] network protocols does the Celerra support?
nas_fs -n testfs1 -create size=500G pool=clar_r5_performance -option slice=yes
Your customer would like to better understand how AVM utomatically creates filesystems.
Given this CLARiiON configuration, how will AVM satisfy the following file system request
(assuming no file systems already exist).
nas_fs -n testfs1 -create size=500G pool=clar_r5_performance -option slice=yes