In what type of file is backup data stored in an EMC Avamar storage node?
In what type of file is backup data stored in an EMC Avamar storage node?
What is the minimum seek time required to pass the benchmark test of a single-node, 3.3 TB EMC Avamar?
What is the minimum seek time required to pass the benchmark test of a single-node, 3.3 TB EMC Avamar?
Which command is used to configure basic networking on an EMC Avamar node?
Which command is used to configure basic networking on an EMC Avamar node?
Using the probe.xml file shown below, what is the IP address of this node?
The mapall command reports an error with node 0.1. Using the probe.xml file shown below, what is the IP address of this node?
<dpn>
<module name=”avaexam”>
<node type=”utility”>
<network-interface>
<address value=”10.6.249.87″/>
</network-interface>
</node>
<node type=”storage”>
<network-interface>
<address value=”10.6.249.88″/>
</network-interface>
</node>
<node type=”storage”>
<network-interface>
<address value=”10.6.249.89″/>
</network-interface>
</node>
<node type=”storage”>
<network-interface>
<address value=”10.6.249.90″/>
</network-interface>
</node>
<node type=”storage”>
<network-interface>
<address value=”10.6.249.91″/>
</network-interface>
</node>
<node type=”spare” connected=”false”>
<network-interface>
<address value=”10.6.249.92″/>
</network-interface>
</node>
</module>
</dpn>
Which component should be stopped and started, before and after specifying the e-mail home smtp server?
Which component should be stopped and started, before and after specifying the e-mail home smtp server?
What does an EMC Avamar Accelerator node provide?
What does an EMC Avamar Accelerator node provide?
How can this be achieved?
A customer is currently running a 1 x 2 Avamar server with 1 TB nodes. In order to add new clients to their Avamar environment, the customer needs more capacity.
How can this be achieved?
By default, what does the asktime utility do when executed on the utility node?
By default, what does the asktime utility do when executed on the utility node?
What is the minimum amount of RAM required on an EMC Avamar NDMP accelerator node to back up two simultaneous
What is the minimum amount of RAM required on an EMC Avamar NDMP accelerator node to back up two simultaneous streams from a NAS filer?
According to EMC Avamar best practices, what is the maximum ratio of database data to file system data that a
According to EMC Avamar best practices, what is the maximum ratio of database data to file system data that a customer’s environment should have?