What is considered to be a thin unfriendly environment?
What is considered to be a thin unfriendly environment?
How should you recommend the host storage be provisioned on the VMAX array?
A customer wants to implement virtual provisioning on a new VMAX array and is concerned about efficient use of available storage and application performance.
The VMAX environment will have file system, database and document repository hosts. The customer reports the system hosts append data to the file system, the database hosts use auto-extend and the document repository hosts have low performance and growth requirements.
How should you recommend the host storage be provisioned on the VMAX array?
What will happen to a thin R2 device when a thin R1 device extent is promoted?
An SRDF/S customer has implemented FAST VP at R1 and R2 sites. What will happen to a thin R2 device when a thin R1 device extent is promoted?
Which FAST policy would best lend itself to the chargeback system?
A Symmetrix VMAX is configured with FAST DP. It contains three tiers of storage:
1. 200 GB RAID 5 (3+1) EFD
2. 300 GB RAID 1 15K RPM Fibre Channel
3. 1 TB RAID 6 (6+2) 7200 RPM SATA
The storage administrator would like to charge each department that uses the VMAX for the amount and class of storage they use. Which FAST policy would best lend itself to the chargeback system?
What would be the recommended value for the relocation rate?
You are implementing a FAST VP solution for a customer and want to start with a conservative FAST VP relocation rate. What would be the recommended value for the relocation rate?
What is a valid FAST VP policy that would be recommended by Tier Advisor?
What is a valid FAST VP policy that would be recommended by Tier Advisor?
What is a valid FAST policy?
What is a valid FAST policy?
What is the minimum number of Flash drives you should recommend not including hot spares?
You are designing tiered storage for a new 2-engine VMAX. What is the minimum number of Flash drives you should recommend not including hot spares?
Which FAST VP control parameter defines the amount of time FAST VP should wait after a thin device is brought
Which FAST VP control parameter defines the amount of time FAST VP should wait after a thin device is brought under FAST VP control before performing a data movement?
Which FAST VP control parameter specifies the maximum amount of time over which long term activity rates will
Which FAST VP control parameter specifies the maximum amount of time over which long term activity rates will decay?