Which kind of device can be used for storing data in a FAST VP tier?
Which kind of device can be used for storing data in a FAST VP tier?
Which EMC resource should be used to research the error?
A customer contacts you with an unfamiliar error he found in the Celerra log for server_2. Which
EMC resource should be used to research the error?
Which solution should be proposed?
A customer plans to implement FAST VP on their Symmetrix VMAX arrays. They will use three
Virtual Pool tiers as shown below.
Tier Name Allocation Percent
T1_EFD 20%
T2_FC_15K 50%
T3_SATA_7R5 100%
Two storage groups S1 and S2 are associated with the policy. The application running on S1 is
more performance sensitive than the one on S2 and its storage needs to be relocated more
quickly when the need arises.
Which solution should be proposed?
Is the zone information listed below a valid zone configuration for a CNS Control Station attached to a CLARii
Is the zone information listed below a valid zone configuration for a CNS Control Station attached
to a CLARiiON?
Zone 0: CS0 HBA0, SPA0, SPB0
Zone 1: CS0 HBA1, SPA1, SPB1
Which is a valid FAST policy?
The storage on a Symmetrix VMAX is divided into four static tiers:
TierA contains RAID 5 (3+1) Enterprise Flash Drives (EFDs)
TierB contains 2-Way-Mir 15K RPM Fibre Channel drives
–TierC contains RAID 5 (7+1) 10K RPM Fibre Channel drives
TierD contains RAID 6 (6+2) SATA drives
Which is a valid FAST policy?
Where is the "External Control Station maintenance LAN" connected?
Where is the “External Control Station maintenance LAN” connected?
you need to check?
You are planning to install Symmetrix Performance Analyzer (SPA) on a Microsoft Windows host.
You want to verify that SPA will be able to collect data from an attached Symmetrix array. You will
only be using the Advanced Diagnostics view for troubleshooting.
Which configuration setting do you need to check?
Which utility is used to access a Control Station remotely from a UNIX host when Telnet is disabled?
Which utility is used to access a Control Station remotely from a UNIX host when Telnet is
disabled?
you need to check?
You are planning to install Symmetrix Performance Analyzer (SPA) on a Microsoft Windows host.
You want to verify that SPA will be able to collect data from an attached Symmetrix array. You will
be using the Real-time Monitoring view for troubleshooting.
Which configuration setting do you need to check?
you need to do to allow the storage administrators to see the other two arrays in SPA?
You have just installed Symmetrix Performance Analyzer (SPA) on a server which already had
Symmetrix Management Console (SMC) installed and working. When one of your storage
administrators launches SPA, they are only able to see three of the five Symmetrix arrays.
What do you need to do to allow the storage administrators to see the other two arrays in SPA?