Which two are additional aspects of physical security should be checked in the new server room?
A new server room is being built. The server room doors should be able to be locked. Which two
are additional aspects of physical security should be checked in the new server room? (Select
TWO)
Which of the following is the MOST likely cause of the problem?
A company plans to upgrade a network server. Before proceeding with the upgrade, the HCL
(Hardware Compatibility List) and hardware is checked and necessary backups and
documentation are made.
The existing 512 MB of SDRAM is replaced with 1024 MB. The 10 Mbps network card is replaced
with a 10/100 PCI network card. When the server restarts, beeps sound and the server does not
pass the POST.
Which of the following is the MOST likely cause of the problem?
Which two statements are true about software-based RAID?
Which two statements are true about software-based RAID? (Select TWO)
Which two types of SCSI controllers meet this specification?
A server is being set up. A SCSI controller that has a bus width of 16 bits and supports a
maximum of 16 devices is required. Which two types of SCSI controllers meet this specification?
(Select TWO)
Which technology enables a technician to turn on a client running any kind of operating system?
Which technology enables a technician to turn on a client running any kind of operating system?
Which RAID standard combines data striping across drives with mirroring?
Which RAID standard combines data striping across drives with mirroring?
Which of the following is the MOST effective solution to apply FIRST?
A server recently had a RAID controller replaced under warranty by the manufacturer. Since the
repair, the system seems to be generating several write errors, and sometimes does not boot into
the operating system. Which of the following is the MOST effective solution to apply FIRST?
Which three are likely causes of this problem?
After adding three additional IDE hard disks and a SCSI DVD-RW drive to an existing server, the
server no longer boots. The original IDE drive is still configured as a master on the primary IDE
channel. After multiple attempts at resetting the server, only two devices attached to the
secondary IDE channel appear during POST.
Which three are likely causes of this problem? (Select THREE)
Which two configurations can be used?
A UNIX server has three 60 GB hard drives. A fault-tolerant array needs to be implemented.
Which two configurations can be used? (Select TWO)
Which server hardware feature enables you to install a new disk drive, or remove and replace a failed disk dri
Which server hardware feature enables you to install a new disk drive, or remove and replace a
failed disk drive, without shutting down the operating system or powering off the system?