Which of the following does the administrator need to do to allow enough time to work on the system to trouble
After a critical service failure occurs the server keeps rebooting every fifteen minutes not giving an
administrator enough time to troubleshoot the failure. Which of the following does the
administrator need to do to allow enough time to work on the system to troubleshoot the problem?
Which of the following is the NEXT step to start rebuilding the array?
After a server inspection, an administrator notices a single drive failure on a server configured with
RAID 5. Which of the following is the NEXT step to start rebuilding the array?
Which of the following meets these requirements?
A high availability solution must be designed for a single file server. Data must be replicated
between the disks to ensure a failure of one disk does not bring down the server. Which of the
following meets these requirements?
Which of the following archiving methods only backs up data that has changed since the previous backup?
Which of the following archiving methods only backs up data that has changed since the previous
backup?
Which of the following should be done FIRST to bring the critical applications online?
A failure of the primary data center has occurred. A warm site is available for use. Which of the
following should be done FIRST to bring the critical applications online?
Which of the following is the cause of this issue?
An SNMP alert has been generated by a server in the main data center. The alert stated that the
internal temperature of the server has exceeded the threshold. No other servers in the rack have
experienced problems, and no other alerts have come from that server about any other events.
Which of the following is the cause of this issue?
Which of the following could have been done prior to making these changes to make it more transparent to users
A company has recently switched ISPs and is being assigned a new block of public addresses.
The public web and FTP servers must be re-addressed to support this change. After changing IP
addresses and updating the DNS records many customers have reported that they are not able to
access the web or FTP servers. Which of the following could have been done prior to making
these changes to make it more transparent to users?
Which of the following BEST explains the problem?
A disk drive failed in a RAID 5 array. After replacing the disk drive, users are still reporting that
access to the server is very slow. Which of the following BEST explains the problem?
All of the following are contained in a server baseline document EXCEPT:
All of the following are contained in a server baseline document EXCEPT:
Which of the following is the minimum number of drives in an RAID 10 configuration?
Which of the following is the minimum number of drives in an RAID 10 configuration?