Which of the following is a benefit of application virtualization?
Which of the following is a benefit of application virtualization?
Which of the following is the MOST likely to cause a server power supply fan to fail but allows the power supp
Which of the following is the MOST likely to cause a server power supply fan to fail but allows the
power supply to still be functional?
Which of the following are the MOST likely causes of the problem?
A server has lost communication to its drives located on a fiber channel SAN. An administrator
notices that the indicator lights on both the HBA and the SAN switch are not lit. Which of the
following are the MOST likely causes of the problem? (Select THREE).
Which of the following is the MOST likely cause of the reboots?
A Windows server has rebooted by itself several times. There are several functioning non- Windows
servers in the same rack that are connected to the same uninterruptible power supply (UPS). Which
of the following is the MOST likely cause of the reboots?
Which of the following utilities would MOST likely be used to initialize the rebuilding of the replacement dri
A server has had a drive fail in its storage RAID set. The administrator swaps the drive with a
replacement and the RAID set does not automatically start to rebuild the replaced drive. Which of
the following utilities would MOST likely be used to initialize the rebuilding of the replacement
drive?
Which of the following is the NEXT step?
An administrator installs a new network card in a properly functioning DC. During the Windows boot
up process the DC bluescreens. Which of the following is the NEXT step?
Which of the following is the MOST likely cause of the problem?
The staff is not able to access a database server. The server has an ‘Operating System not found’
error and is set to boot from a fiber channel SAN. All other database servers are set to boot from the
SAN and access the same switch and data as this database server. Which of the following is the
MOST likely cause of the problem?
Which of the following does the administrator need to do to allow enough time to work on the system to trouble
After a critical service failure occurs the server keeps rebooting every fifteen minutes not giving an
administrator enough time to troubleshoot the failure. Which of the following does the
administrator need to do to allow enough time to work on the system to troubleshoot the problem?
Which of the following is the NEXT step to start rebuilding the array?
After a server inspection, an administrator notices a single drive failure on a server configured with
RAID 5. Which of the following is the NEXT step to start rebuilding the array?
Which of the following meets these requirements?
A high availability solution must be designed for a single file server. Data must be replicated between
the disks to ensure a failure of one disk does not bring down the server. Which of the following
meets these requirements?