PrepAway - Latest Free Exam Questions & Answers

what troubleshooting step would you do first when having a npv issue?

In a Cisco Data center network, what troubleshooting step would you do first when having a npv issue?

PrepAway - Latest Free Exam Questions & Answers

A.
Check to see if npv is enable

B.
Check name server database to see if it recognizes device

C.
Check detail config of FCNS database

D.
Check the show-tech-support detail

One Comment on “what troubleshooting step would you do first when having a npv issue?

  1. Jorge says:

    NP Uplink ports on NPV edge switch are stuck in initializing state

    NP uplink ports connected to the core NPIV switch do not come online and are stuck in an initializing state.

    Possible Cause

    The core switch might not have been enabled for NPIV.

    Example:

    switch(config-if)# sh int fc2/2

    fc2/2 is down (Initializing)

    Hardware is Fibre Channel, SFP is short wave laser w/o OFC (SN)

    Port WWN is 20:42:00:0d:ec:a4:3b:80

    Admin port mode is NP, trunk mode is on

    Solution

    •Check the status of the NPV external interfaces.
    Check that the NPIV is enabled on the core switch.

    Example:

    switch(config-if)# sh npv status

    npiv is disabled

    disruptive load balancing is disabled

    External Interfaces:

    ====================

    Interface: fc2/1, State: Failed(NPIV is not enabled in upstream switch)

    Interface: fc2/2, State: Failed(NPIV is not enabled in upstream switch)

    Interface: san-port-channel 200, State: Down

    •If NPIV is disabled, then enable NPIV on the core switch.

    Example:

    switch(config)# feature npiv

    http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus5000/sw/troubleshooting/guide/N5K_Troubleshooting_Guide/n5K_ts_sans.html#wp1024550