A customer is having a problem forming a Brocade VCS Fabric on interface Te 11/0/4.
Interface TenGigabitEthernet 11/0/4
Identifier 3 SFP
Connector 7 LC
Transceiver 0000000000000010 10_GB/s
Name sw
Encoding 6
Baud Rate 103 (units 100 megabaud)
Length 9u 0 (units km)
Length 9u 0 (units 100 meters)
Length 50u 8 (units 10 meters)
Length 62.5u 3 (units 10 meters)
Length Cu 0 (units 1 meter)
Vendor Name BROCADE
Vendor OUI 00:05:1e
Vendor PN 57-0000075-01
Vendor Rev A
Wavelength 850 (units nm)
Options 001a
BR Max 0
BR Min 0
Serial No AAF212330000J95
Date Code 120816
Optical Monitor yes
Temperature 34 Centigrade
Voltage 3277.2 (mVolts)
Current 7.944 (mAmps)
TX Power 638.5 (uWatts)
RX Power 0 (uWatts)
Referring to the exhibit, which action will resolve this problem?

A.
Reboot the VDX switch.
B.
Disable and re-enable port Te 11/0/4 to increase RX power.
C.
Replace the fiber cable in port Te 11/0/4 to increase RX power.
D.
Re-seat transceiver in Te 11/0/4.