You need to manage a C7000 enclosure with HP OneView, but the Virtual Connect
modules in the enclosure do not meet the minimum firmware requirements. What should
you do to manage the enclosure?

A.
Add an enclosure to HP OneView so that the firmware will be automatically updated to
the latest version.
B.
Replicate firmware from the Virtual Connect modules with the minimum supported
firmware.
C.
Upload the latest Virtual Connect firmware to the Onboard Administrator and let the
Virtual Connect modules automatically update the firmware.
D.
Update the Virtual Connect modules using the Virtual Connect Support Uti.ity (VCSU)
before add.ng the enclosure to HP OneView.
Explanation:
The HPE BladeSystem c-Class Virtual Connect Support Utility enables administrators to upgrade VC-Enet and VC-FC firmware, and to perform other maintenance tasks remotely on both BladeSystem c-Class c7000 and c3000 Enclosures using a standalone command line utility.
If an interconnect has an earlier version of HP Virtual Connect firmware, HP recommends using the VCSU (Virtual Connect Support Utility) to update the firmware to version 3.15, at least, before adding the device to the appliance.
HP OneView will automatically update the OA, servers’ BIOS, and iLOs to the firmware version defined as the baseline or to the minimum required by HP OneView, if no baseline has been set. Virtual Connect InterConnect firmware is managed separately via the logical interconnect. Navigate to the logical interconnect and use the Update firmware action to update the Virtual Connect interconnect firmware.
CORRECT: D
0
0
A
http://h20195.www2.hp.com/V2/GetPDF.aspx/4AA5-0351ENW.pdf
0
0
HP OneView consolidates configuration, firmware management, backup/restore,
and monitoring functions which were provided by separate tools in the Virtual Connect
management environment.HP OneView replaces Virtual Connect Manager and Virtual Connect
Enterprise Manager when the enclosure is imported into HP OneView. Virtual Connect Manager is
no longer available and cannot be logged into once the enclosure is managed by
HP OneView.
http://h20195.www2.hp.com/V2/GetPDF.aspx/4AA5-0351ENW.pdf
A is the answer. check the doc’s page 6 and beyond
0
0
HPE OneView will automatically update the OA, servers’ BIOS, and iLOs to the firmware version defined as the baseline or to the minimum required by HPE OneView, if no baseline has been set. Virtual Connect interconnect firmware is managed separately via the logical interconnect. Navigate to the logical interconnect and use the Update firmware action to update the Virtual Connect interconnect firmware.
the answer must be “D” according to this statement in your link
0
0
HP OneView replaces Virtual Connect Manager and Virtual Connect
Enterprise Manager when the enclosure is imported correct… at the moment it s not imported so VCSU needs to be used .
0
0
So the answer is
D.
Update the Virtual Connect modules using the Virtual Connect Support Uti.ity (VCSU)
before adding the enclosure to HP OneView.
0
0