Which command should the customer issue from the recovery CCI server to suspend the Universal Replicator pairs

A customer is replicating data between sites using Universal Replicator. The Universal
Replicator Command Control Interface (CCI) device group name is UR_db01. A power
outage occurred at the production site and the users have moved to the recovery site. The
production disk array, CCI server, and network equipment are still running on generator
power. Which command should the customer issue from the recovery CCI server to suspend
the Universal Replicator pairs and reverse the replication direction?

Which two CCI commands will accomplish this objective?

A customer is using ShadowImage on a Universal Storage Platform 1100 to create point-intime copies of a database every two hours. The production data is contained on 72GB RAID-
1 parity groups and the secondary volumes are contained on 300GB RAID-6 parity groups.
The customer is running the latest Command Control Interface (CCI) version on a Solaris
server using the korn shell. The CCI device group name for the ShadowImage volume is
SI_db01. The customer discovers data corruption on the production volumes and wants to
restore from the last ShadowImage copy while maintaining RAID-1 for the production
volumes. Which two CCI commands will accomplish this objective? (Choose two.)