Why does CIFS replication not failover to the target VNX during the DR test?

A customer has two EMC VNX configured to replicate between sites. Each VNX has dual Control
Stations. The primary Control Station at the source site fails at 6 p.m. and reboots. At 8 p.m., the
customer completes DR testing and observes CIFS replication does not failover to the target site
VNX. Why does CIFS replication not failover to the target VNX during the DR test?

What is the source of the performance difference between the file and block configurations?

A customer has two identically configured Linux hosts (OS version, memory, CPU) attached to the
same network. One host is NFS-attached and the other is FC-attached to an EMC VNX. Both the
NFS file systems and the SAN LUNs are created from four RAID 5 (4+1) RAID groups. LUNs are
not shared between file and block.
The customer reports NFS-attached host is able to achieve much greater throughput via NFSv4
versus the FC-attached host.
What is the source of the performance difference between the file and block configurations?

What is the recommended SAS LCC port configuration for optimal performance?

A client has an EMC VNX configured with four storage ports, four 15-drive DAEs (disk array
enclosures) and a total of forty drives (20 NL-SAS and 20 SAS drives). The client is using RAID 5
(4+1) RAID groups with a traditional LUN configuration.
What is the recommended SAS LCC port configuration for optimal performance?

What is the source of the performance difference between the file and block configurations?

A customer has two identically configured Linux hosts (OS version, memory, CPU) attached to the
same network. One host is NFS-attached and the other is FC-attached to an EMC VNX. Both the
NFS file systems and the SAN LUNs are created from four RAID 5 (4+1) RAID groups. LUNs are
not shared between file and block and each host generates the same size I/O.
The customer reports the FC-attached host is able to achieve much greater throughput than the
NFS-attached host.
What is the source of the performance difference between the file and block configurations?

What is the most likely reason for the performance issue?

A customer has two EMC VNX, one at the primary site and the other at a DR site located 100 km
away. The WAN connection between sites is a 100 Mb/s dark fiber link with 4 ms latency.

A previous storage administrator configured the pool LUNs for the file system on thin LUNs. The
file system is growing at a rate of 500 GB per week and is on a VDM. The new storage
administrator reports performance issues with the file system.
What is the most likely reason for the performance issue?