Why is he unable to write a new file?
Replicate2 – 76GB
Your customer is concerned that the memory requirements for SnapSure and Celerra Replication on the same Celerra may affect the performance characteristics of other Celerra applications. The customer is planning to checkpoint and replicate the following filesystems.
For planning purposes (on the Primary Celerra only), you estimate that the SavVol sizes will be 10% of the filesystem size.
Estimate the amount of memory that will be required on the Celerra for SnapSure and Celerra Replicator.
Planning one checkpoint for each of the following filesystems
PFS1 – 50GB
PFS2 – 220GB
PFS3 – 157GB
Planning replication of the following filesystems to a remote Celerra
Replicate1 – 135GB
Replicate2 – 76GB
What could be causing his performance issues?
What would you recommend?
Your customer would like to use ATA drives for their SnapSure SavVol. The I/O access pattern on the PFS is random read. They plan to access the checkpoints randomly as well.
What would you recommend?
How would you suggest the customer configure new file systems for best performance?
Your customer has recently purchased eight 146GB drives for his DMX that will be configured in a RAID5 3+1 configuration.
How would you suggest the customer configure new file systems for best performance?
Which tool should be used to copy CIFS filesystem ACL’s?
Which tool should be used to copy CIFS filesystem ACL’s?
What would you suggest to address this concern?
The customer would like to implement CAVA and a DHSM solution in his W2K3 environment. The customer is concerned about the time it takes to write a file to a DHSM drive on a secondary storage.
What would you suggest to address this concern?
What is the cause of this error?
You have set the local security policies on the source Windows 2003 server and rebooted in preparation for a CDMS migration. You log into another server as the migration user in the domain admins group. You test access to the source by trying to map to the source share and get an access denied error.
What is the cause of this error?
What is the issue?
The Celerra iSCSI LUNs are visible on the Windows hosts. The formatting of the LUNs stops at 100% and never fully completes.
What is the issue?