PrepAway - Latest Free Exam Questions & Answers

Which two of the following CPMAD parameter types combine to specify the rate of occurrence of an attack before

Which two of the following CPMAD parameter types combine to specify the rate of occurrence of
an attack before action is taken? (Choose all that apply)

PrepAway - Latest Free Exam Questions & Answers

A.
Repetitions

B.
Resolution

C.
Time_interval

D.
Clean_interval

E.
Interval_between_connection_attempts

F.
Number_of_connection_attempts

Explanation:

: The “MAD_syn_attack_repetitions” CPMAD parameter list the number of unique events that
must be recorded within interval seconds in order for the action specified to be taken. The
“MAD_syn_attack_time_interval” is the amount of time, in seconds, that attack information is
stored within the internal MAD memory tables. The combination of both parameters specify the
occurrence of an attack before an action is taken. See Page 410 of Syngress Book “Checkpoint
NG – Next Generation Security Administration”.